Philips XX1080 Image Intensifier Tube
Tube intensificateur d'image
Bildverstärkerröhre
First generation image amplifier for nightvision devices
NSN (National Stock Number): 5960-17-037-7118
• Spectral response: < 450 nm to > 850 nm
• Cathode: S25
• Gain: 30 cd/lm
• Sensitivity: 125 µA/lm
• Screen: P20 phosphor (green)
• Max anode voltage: 15.4 kV
• Focus voltage: 450 V (max 500 V)
Figures with 14 kV anode voltage:
• Light amplification (20 mm diameter) >= 1000
• Distortion (50 mm diameter): 1%
• Center resolution: 20 lp/mm
• Throughput: 90% at 2.5 lp/mm, 55% at 7.5 lp/mm; 25% at 16 lp/mm
• Minimum background light: 0.2 µlx
• Photocathode sensitivity: 15 mA/W at 800 nm; 10 mA/W at 850 nm
Hauteur • Height • Höhe : 106 mm • 4" 1/8
Diamčtre • Diameter • Durchmesser : 63 mm • 2" 1/2
Le contenu de ce site est sous copyleft The content of this site is under copyleft Der Inhalt dieser Website steht unter Copyleft