ITT FW-114 Ultra-Fast Biplanar Phototube 300-700 nm
Photodétecteur de rayons gamma
Gamma-Detektor
The FW-114 is a 2.25 inch diameter high current biplanar photodiode designed by ITT for efficient
optical coupling to an appropriate scintillator. This scintillator may take the form of a transparent solid or liquid
accommodated within the faceplate cavity of the tube or a multicrystalline phosphor directly on the faceplate of the
tube, depending on the type of radiation to be detected.
The FW-114 has found particular use for the monitoring of high intensity gamma radiation of short
duration. The wide dynamic range of the FW-114 permits observation of the shape of these pulses down to very small
fractional parts of the original pulse heights, as well as measurement of pulses of widely varying amplitude.
Excellent saturation and linearity characteristics are assured in the FW114 by the plane, parallel (biplanar)
electrode configuration.
Minimum Wavelength: 300 nm
Rise Time: 500 picoseconds
Peak Wavelength: 500 nm
Maximum Wavelength: 700 nm
Fiche technique • Data sheet • Datenblatt:
FW114.pdf &
FW114A.pdf &
ITT Electro-Optic Devices - Data Summary
Thanks to Peer Hofstra who provided data about this tube.
Hauteur • Height • Höhe : 46 mm • 1" 8/10
Diamètre • Diameter • Durchmesser : 57 mm • 2" 2/10
Le contenu de ce site est sous copyleft The content of this site is under copyleft Der Inhalt dieser Website steht unter Copyleft