ITT F4000 (S50UVG) Ultra-Fast Vacuum Biplanar Phototube
Photodétecteur de rayons gamma
Gamma-Detektor
This is a biplanar phototube for applications that require fast response monitoring of high intensity
radiation. With a rise time of less than 500 picoseconds, detailed examination across nine orders of magnitude can be made in the
gigahertz range. With an S-5 cathode and associated scintillator, the F4000 is well suited to monitoring short bursts of gamma
radiation.
Length: 48 mm
Diameter: 57 mm
Anode Mesh Optical Transmission: 80%
Resistance of Anode Mesh: 0.5 O/sq.
Typical Operating Voltage: 2.5 kV
Photocathode Spectral Response: S-5
Typical Photocathode Luminous Sensitivity: 30 µA/lm
Photocathode Peak Radiant Sensitivity: 4x10-2 A/W
Maximum Peak Current Output: 5.0 A
Maximum Average Current Output: 75 µA
Deviation From Linearity: 10 %
Maximum Dark Current: 5x10-9 A
Interelectrode Capacitance: 1 pF
Rise Time: 5x10-10 s
Thanks to Peer Hofstra who provided data about this tube.
Hauteur • Height • Höhe : 145 mm • 5" 7/10
Diamètre • Diameter • Durchmesser : 89 mm • 3" 1/2
Le contenu de ce site est sous copyleft The content of this site is under copyleft Der Inhalt dieser Website steht unter Copyleft