home en fr de <-- ^ -->

Philips Research Labs, Experimental Cathodes
Cathodes expérimentales
Versuchskathoden

All these tubes were found in a Philips research laboratory in Eindhoven (The Netherlands).

Several of these cathodes, essentially intended for cathode-ray tubes, have been the subject of research conducted by Jan Hasker and his team.

Jan Hasker was born in Groningen, The Netherlands, on March 25, 1935. In 1958 he passed the preliminary examination for the doctor’s degree in physics at the Groningen State University and received the PhD degree in 1969 in technical sciences from the Technological University, Eindhoven, The Netherlands, with the dissertation, “Initial-Velocity Effects in Cathode-Ray Tubes.”
At Groningen, he participated in the research program on nuclear physics. In 1959, he joined Philips Research Laboratories at Eindhoven. There he worked in the fields of electron optics on CRT’s (initial-velocity effects, beam-indexing color display), gaseous discharges (efficient low-pressure lamps with high radiation output per unit volume by the introduction of a tenuous recombination structure into the discharge volume), and thermionic emission (fast oxide-coated cathodes with a low heating power and decreased operating temperature, properties of current-voltage characteristics, scandate cathodes). Moreover, he participated in various teaching programs (Eindhoven University of Technology, TU/e).

European Patent 0317002A1 (1988) Scandate cathode.

 

Philips Research Labs, Experimental Cathodes

Reservoir Cathode

AW53-88 Gun

AW53-88 Black & White Television Picture Tube

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

0,9 Ø Sc 11-"80
Scandium

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

ES 883 4:1:1 geimpv 5000 Ä OsRu Ø1,2 15-12-'86
Osmium/Ruthenium

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

1,2 Ø Sc 11-"80
Scandium

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

Ø 1,2 Sc 11-"80
Scandium

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

E.S.989-4.1.1 5000 A Os.Ru Afgedraaid 24-9-'87
Osmium/Ruthenium

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

E.S.673 top/W+Ga2O3 4:1:1
Tungsten + Gallium(III) Oxide

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

E.S.745 top/W+SC2O3 95/5 4:1:1
Tungsten + Scandium(III) Oxide

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

E.S.398 5:3:2 + Os-Ru 17-6-'82
Osmium/Ruthenium

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

2 W OXYDE

Philips Research Labs, Experimental Cathode Philips Research Labs, Experimental Cathode

E.S.398 Vacuum 5:3:2+Os-Ru 17-6-'82
Osmium/Ruthenium

Philips Research Labs, Experimental Cathodes

90 SrAl4/10BaAl4 +Ni 80:20
SrAl4 = Strontium Aluminide, BaAl4 = Barium aluminide

Philips Research Labs, Experimental Cathodes

Ø1,8 5:3:2 +5% Ba3Sc4O9 12-1-78
Ba3Sc4O9 = Tribarium Scandate

Philips Research Labs, Experimental Cathodes

Ø 1,8 5:3:2 +5% Ba3Sc4O9 12-1-78
Ba3Sc4O9 = Tribarium Scandate

Philips Research Labs, Experimental Cathodes

40-60 "L" +6000Å Os/Ru 19-12-79 HASKER
Osmium/Ruthenium

Philips Research Labs, Experimental Cathodes

"L" PET + 5000Å OS 1600° 2° HASKER
Osmium

Philips Research Labs, Experimental Cathodes

O6,5000 A° 30 SEC 1500°

Philips Research Labs, Experimental Cathodes

BaAl4+Ni 80-20
Barium aluminide + Nickel

Philips Research Labs, Experimental Cathodes

Philips Research Labs, Experimental Cathodes

SrAlB + BaAl4 90/10 SrBaAl4 + N/80-20
Strontium-Boron-Aluminum + Barium Aluminide + Strontium-Barium Aluminide

 


Le contenu de ce site est sous copyleft - The content of this site is under copyleft - Der Inhalt dieser Website steht unter Copyleft