General Electric Coolidge Tube XP-2.4.5.
Tube à rayons X
Röntgenröhre
			  Dual focus diagnostic tube, ca. 1930s or 1940s.
              "XP" means "X-ray Protected".
              "2" indicates that one of the tube's two filaments produces a fine to medium focus.
              "4.5" indicates that the other filament produces a broad focus (this number indicates the 
              approximate diameter of the projected focal spot in mm).
              The "XP" General Electric tubes have a 20-deg. anode and an elongated focal spot as 
              introduced by Benson in 1916. 
              See also • Voir aussi • Siehe auch :
General Electric Coolidge Tube XP-2-4.5 with protective sheath
			   
			  
			  Click to enlarge
			  Longueur • Length • Länge : 48,5 cm • 19" 1/16
              Diamètre • Diameter • Durchmesser : 6 cm • 2" 3/8
              
              
              
              
			  
              
               
Le contenu de ce site est sous copyleft  The content of this site is under copyleft
 The content of this site is under copyleft  Der Inhalt dieser Website steht unter Copyleft
 Der Inhalt dieser Website steht unter Copyleft